<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15197</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: Unload vacuum sensed plate before vacuum turned on, check Unload Vacuum Threshold
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Platesetter_3244</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Check the value of uvt.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Check that there is no plate on the picker.
</text></DescriptionText>
</OperatorAction>
<Cause>
During a process, the plate is fed into the bridge (with the bridge belts (cbelt)
running)and then the belts are stopped. Then the unload vacuum is released and the
unload cups retracted and after 1 second the brige belts started again.
The vacuum is is checked before the belts are restarted just to make sure that it is
at least below the grip threshold
(uvt), if not then this error is reported, unsolicited, log only.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/sat_cal_uvt.xml</LinkAddress><LinkTitle>NVS: sat uvt</LinkTitle></Link>
<Link><LinkAddress>../commands/uvac.xml</LinkAddress><LinkTitle>Command: uvac</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:56 2008 PST
</Updated>
<Links>
</Links>